NEMA Enclosure Kits with AirTight 802.11n Sensor
Pre-assembled Solutions for Easy, Secure, Weatherproof Deployment
Covered by AirTight warranty and support Download datasheet
Sturdy and Reliable for Hazardous Environments
AirTight offers two different SpectraGuard Sensor Assemblies in NEMA approved enclosures:
- a sealed unit - for indoor use or for outdoor use in moderate temperature environments
- a heated/cooled unit - for outdoor use in more extreme weather conditions
The enclosure protects against environmental hazards and keeps the 802.11n sensor and installation safe.
- Protects against moisture, corrosive elements
- Protects against theft or damage
Fast, Complete Installation
The pre-assembled enclosures facilitate quick installation. You save time and save money in installation costs.
Installation Guidelines
- The NEMA units can be mounted indoors - on interior walls or inside false ceiling, or outdoors - on exterior walls, utility poles or other outdoor fixtures.
- The antennas should be properly mounted following guidelines provided with the assemblies.
- AirTight strongly recommends that customers use a licensed electrician/contractor for installation and follow local building codes.

A sample outdoor deployment of 802.11n sensor in NEMA enclosure with Two single-band external antennas each for 2.4 and 5 GHz bands (Figure 1) OR One dual-band (2.4/5 GHz) 6-pack MIMO external antenna (Figure 2)
Detailed installation guidelines are provided with the assemblies.
Power Requirements
The SpectraGuard Sensor requires 802.3af POE.
The heated/cooled unit requires 120V AC power to the unit to run the heater and fan.
List of Components
The NEMA enclosure kits include the following components:
- AirTight SS-300-AT (802.11n) SpectraGuard Sensor
- NEMA enclosure (Sealed unit or Heated/cooled unit)
- Two single-band external antennas each for 2.4 and 5 GHz bands (Figure 1) OR One dual-band (2.4/5 GHz) 6-pack MIMO external antenna (Figure 2)
- Required connectors
- Four lightning arrestors and four 20 foot low loss cables (not applicable for 6-pack MIMO antenna)
The assemblies DO NOT include the following, which the customer must supply:
- Ethernet cable, POE injector
- Grounding cables/kit
- Power cable for heated/cooled unit
- NEMA mounting kit
Detailed Specifications
| Enclosure Specifications | Sealed Unit | Heated/Ventilated Unit |
| Enclosure Material | Fiberglass reinforced polyester | Fiberglass reinforced polyester |
| Enclosure Color | Machine grey | Machine grey |
| Enclosure Flame Rating | UL 94-5V | UL 94-5V |
| RoHS Compliant | Yes (both enclosure and lightning arrestor) | Yes (both enclosure and lightning arrestor) |
| Enclosure Ratings | NEMA 4X/IP65 | NEMA 3R/IP42 |
| Outside Dimensions | 15.5 x 13.5 x 7.7 inches | 15.5 x 13.5 x 8.7 inches |
| Weight | 18.7 lbs | 20.6 lbs |
| Mounting | Pre-drilled mounting holes in enclosure | Pre-drilled mounting holes in enclosure |
| Operating Temperature Range | 5º to 50º C |
Heater
operates below 10º C, fan operates above 45º C |
| Fan operates above 45º C | 10 Watts | |
| Humidity | Up to 95% non-condensing | Up to 95% non-condensing |
| Power Requirements | Sensor requires 802.3af PoE |
Fan &
heater require 120V AC, Sensor requires 802.3af PoE |
| Grounding Specifications | As specified by local building codes | As specified by local building codes |
| Lightning Protector Electrical Specifications | ||
| Frequency Range | 0-6 GHz 0-6 GHz | 0-6 GHz 0-6 GHz |
| VSWR | 1:1.5 Max (0-6GHz) | 1:1.5 Max (0-6GHz) |
| Insertion Loss | 0.5 db Max (0-6GHz) | 0.5 db Max (0-6GHz) |
| Impedance | 50 Ohm | 50 Ohm |
| Gas Tube Breakdown Voltage | 90V ± 20% | 90V ± 20% |
| Gas Tube Impulse Breakdown Voltage | 1000V ± 20% | 1000V ± 20% |
| RF Power Rating (CW) | 10W Continuous | 10W Continuous |
| Cable and Antenna Specifications | ||
| Antenna Cable Length | Four 20 feet low-loss cables | Four 20 feet low-loss cables |
| Antenna Cable Specs | Attenuation = 6 to 11 db per 100 feet | Attenuation = 6 to 11 db per 100 feet |